SHR AUTOSENSOR TECH LIMITED Engineering RFQ Support

10KV Kontakt 24V Spule Hochspannungs-Reed-Relais HVR24-1A10-06-150

Technical product information for engineering review. Request datasheet, samples, pricing, lead time, or a cross-reference recommendation for this part.

Angebot anfordern Querverweis

Sale!

10KV Contact 24V Coil High Voltage Reed Relay HVR24-1A10-06-150

Original price was: $55.00.Current price is: $45.00.

Product Features
Breakdown Voltage up to 10KVDC
Coil Voltage 24V
Niedriger Kontaktwiderstand
Excellent lifetime Characteristics
Hermetisch abgedichtet für lange Lebensdauer
Low Contact resistance
Kundenspezifisches Design verfügbar

Sample, Datasheet & Engineering Support

  • Model: HVR24-1A10-06-150
  • Purchase path: Buy sample online
  • Production projects: RFQ recommended for final electrical confirmation.

Download PDF DatasheetRequest Production QuoteSample Store

Primary path is RFQ. Use Buy Sample only for engineering validation quantities.

Buy Sample

Shipping included · In stock · Ships within 72 hours

SKU: 1118808096108 Categories: , Tag:
Model detail

HVR24-1A10-06-150 product details, applications and specifications

Select this family when the design needs compact high-voltage switching, low leakage, clean signal isolation and repeatable switching in test or instrumentation systems. The table below summarizes the key selection points; use the model datasheet for dimensions, ratings and ordering confirmation.

10KV Contact 24V Coil High Voltage Reed Relay HVR24-1A10-06-150 - Hvr24 1a15 04 150 4
High Voltage Reed Relay principle illustration
1High-voltage input
2Hermetic reed switch
3Insulated relay package
4ATE / medical / HV output

Main specifications for RFQ

Public model
HVR24-1A10-06-150
Product family
High Voltage Reed Relays, 10KV Reed Relay
Coil Voltage
24V
Breakdown Voltage
10KVDC
Contact form
1 Form A (series)
Coil resistance
600±10% Ω (series)
Max pull-in voltage
18 VDC (series)
Min drop-out voltage
2 VDC (series)
Max carrying current
5.0 A (series)
Min breakdown voltage
10 kVDC (series)
Max contact resistance
150 mΩ (series)
Isolationswiderstand
1×1012Ω (series)
Reset time
1.5 ms (series)
Capacitance
across open switch1.0 pF (series)
Datasheet
Available as individual PDF for this model

Specifications above are extracted from the live product content for this model. Confirm final ratings, drawings and ordering code through the PDF datasheet or RFQ before production use.

Datasheet-style view

HVR24-1A10-06-150 technical data by section

Grouped specification blocks make this model page easier to scan for engineering selection, RFQ review and sample validation.

Electrical ratings

Breakdown / dielectric
10KVDC
Voltage classes
4kV / 6kV / 10kV / 15kV / 20kV series

Coil / control data

Coil voltage
24V
Spulenoptionen
Model-specific coil voltage; confirm by datasheet/RFQ

Contact / output data

Capacitance
across open switch1.0 pF (series)
Contact forms
1 Form A and series-dependent options

Mechanical & mounting

Insulation focus
High dielectric strength and low leakage signal switching
Mounting
PCB relay, module and custom high-voltage assembly options

Ordering / RFQ notes

  • Confirm exact ordering code, coil voltage, contact form and termination style before purchase.
  • Share load voltage/current, load type, duty cycle, ambient temperature and isolation requirement in RFQ.
  • Use the linked PDF datasheet for package drawing, dimensions and final rating limits.
  • For reed relays, keep switching voltage, stand-off/hold-off voltage and dielectric strength separate during selection.
  • Product family context: High Voltage Reed Relay.
Engineering selection notes

Avoid common specification mistakes

These notes keep product pages useful for engineers while avoiding overclaims. Final ratings remain model- and application-specific.

Separate switching, stand-off and dielectric ratingsSwitching voltage is the voltage the relay may open or close under specified load. Stand-off/hold-off and dielectric ratings are withstand tests and should not be treated as hot-switching capability.
Dry reed relays are low-bounce, not universally zero-bounceUse model datasheets for operate time and bounce behavior. Reserve bounce-free language for mercury wetted contacts or explicitly specified designs.
Load type controls lifeCapacitive inrush, inductive energy and hot-switching conditions can reduce contact life. Confirm load type, duty cycle and safety margin through datasheet review and RFQ.

Typische Anwendungen

  • Semiconductor ATE and wafer probe switching
  • Medical high-voltage diagnostic equipment
  • Cable / insulation / hipot test systems
  • Precision instrumentation and high-voltage multiplexing

What to confirm before purchase

  • Voltage, current, load type and safety margin
  • Contact form, coil voltage and drive circuit
  • Mounting, wiring, environmental and compliance requirements
  • Sample validation quantity and production forecast
FAQ

HVR24-1A10-06-150 ordering FAQ

These visible answers mirror the FAQ structured data and clarify what buyers should confirm before sample approval or production ordering.

What should be confirmed before ordering HVR24-1A10-06-150?

Confirm the exact ordering code, coil or control voltage, contact form or output type, voltage/current rating, mounting style, environmental conditions and validation quantity.

Is a PDF datasheet available for HVR24-1A10-06-150?

Yes. The model page links to an individual PDF datasheet for engineering review and RFQ confirmation.

What applications is this product family used for?

Semiconductor ATE and wafer probe switching, Medical high-voltage diagnostic equipment, Cable / insulation / hipot test systems, Precision instrumentation and high-voltage multiplexing.

Download HVR24-1A10-06-150 Datasheet Request quote for this model Compare all models

English engineering resources

Datasheet, catalog and RFQ support

Download the original source datasheet when available; otherwise use the checked generated English datasheet, family catalog, or RFQ path.

Download English Datasheet Family Catalog Complete Catalog Request Engineering Quote

Original source PDFs are preferred when available. Generated English PDFs are used only when no original source PDF is found; final ratings, drawings and application suitability are confirmed by RFQ.

Description

HVR24-1A10-06-150

10 kVDC Hochspannungs-Reed-Relais, 1 Form A, 24 VDC Spule

Das HVR24-1A10-06-150 ist ein Hochspannungs-Reed-Relais von SHR, das für zuverlässiges Hochspannungsschalten mit langlebigen, versiegelten Reed-Kontakten ausgelegt ist. Es bietet eine minimale Durchbruchspannung von 10 kVDC und eignet sich für Hochspannungstests, medizinische und industrielle Anwendungen.

Wichtigste Spezifikationen

Contact form 1 Form A (series)
Nominal coil voltage 24 VDC (series)
Nominal coil current 40 mA (series)
Coil resistance 600±10% Ω (series)
Max pull-in voltage 18 VDC (series)
Min drop-out voltage 2 VDC (series)
Max contact rating 50 W (series)
Max switching voltage 7.5 kVDC (series)
Max switching current 3.0 A (series)
Max carrying current 5.0 A (series)
Min breakdown voltage 10 kVDC (series)
Max contact resistance 150 mΩ (series)
Dielectric strength, open contacts (min, static) 10 kVDC (series)
Dielectric strength, contact to coil 15 kVDC (series)
Isolationswiderstand 1×1012Ω (series)
Operate time (incl. bounce) 3.0 ms (series)
Reset time 1.5 ms (series)
Capacitance across open switch 1.0 pF (series)
Life expectancy (electrical) 5×107 ops (at 500 VDC 100mA) (series)
Operating temperature -20°C to 70°C (series)
Storage temperature -35°C to 105°C (series)
Washability fully sealed (series)

Voltage clarification: The 10 kV in this model name refers to its minimum breakdown voltage of 10 kVDC; its maximum switching voltage is 7.5 kVDC. Breakdown voltage is a withstand rating, not the hot-switching voltage.

Wichtigste Merkmale

  • Hochspannungs-Reed-Relais
  • Niedriger Kontaktwiderstand
  • Durchbruch bis zu 10 kVDC
  • Hervorragende Lebensdauereigenschaften
  • Kundenspezifisches Design verfügbar

Anwendungen

  • Hochspannungsprüfung und Messtechnik
  • Medizinische Geräte
  • Industriesteuerungen
  • Energiesysteme

Hinweis: Das verlinkte Datenblatt für HVR24-1A10-06-150 ist eine eingescannte Kopie; die angegebenen Spezifikationen stammen aus dem HVR24-1A10-06-Referenzdatenblatt (gleiche Serie) und sind als Seriendaten gekennzeichnet.

Spezifikationen gemäß dem HVR24-1A10-06-Referenzdatenblatt (Ver. 04) (SHR). Angaben zu Außenmaßen und Pinbelegung finden Sie im Datenblatt.

Additional information

Dimensions 15 × 15 × 15 cm
WhatsApp Request a Quote